Titration is a sensitive analytical method that lets you recognize an unknown concentration of a chemical in systems by introducing a known concentration of another chemical. Several factors can reason errors in titration findings, consisting of misreading volumes, failure concentration worths or faulty technique. Treatment must be taken as the systems of the known concentration is introduced right into a specific volume that the unknown v laboratory glassware such as a burette or pipette. Signs are supplied to recognize when a reaction has pertained to an end.

You are watching: Possible sources of error in titration


The end point of a titration is when the reaction in between the two solutions has stopped. Indicators, which adjust color to suggest when the reaction has actually stopped, carry out not change instantly. In the situation of acid-base titration, the indicator may an initial lighten in shade before an altering completely. Also, every individual perceives shade slightly differently, i m sorry affects the outcome of the experiment. If the color has adjusted slightly, too much of the titrant, which comes from the burette, can be introduced into the solution, overshooting results.


The accuracy that titration requires an exact measurement of the volume of materials in use. However markings top top a burette have the right to be easily misread. One means to misread the volume is by looking at the measurement on one angle. Native above, it deserve to seem prefer the volume is lower, while indigenous below, the evident volume look at higher. Another source of measure error is looking in ~ the dorn spot. A solution creates a concave curve and also the bottom the the curve is used to measure up the volume. If the reading is taken native the higher sections of the curve, the volume measurement will be in error.


Errors in concentration directly affect the measurement accuracy. Errors encompass using the wrong concentration to start with, which can take place from chemical decomposition or evaporation that fluids. The equipment may have been prepared incorrectly or contaminatns might have to be introduced right into the solution, such as utilizing dirty equipment. Even the process of cleaning your equipment, if brought out v the dorn solution, can impact the concentrations of the remedies to it is in experimented on.


You have to follow strictly guidelines in handling and also using all equipment during the experiment as the slightest mistake can develop errors in the findings. Because that example, swirling the solution can an outcome in ns of systems that will influence results. Errors in filling the burette can reason air bubbles that influence the flow of the fluid in the burette.


Other human or tools errors can likewise creep in. Person error has using choosing the wrong reagents or making use of the not correct amount the indicator. Devices error generally is in the burette, i m sorry can develop leaks end time. Also a little loss of liquid will influence the results of the titration.